Push Button Remote
0.04 seconds < T < 0.8 seconds
Result
Track Ena-
ble
Click Dynamic (+) to tog-
gle between selections.
Double-pulse the remote line
to toggle between selections.
Sets output 2 identical to
output 1
Tracking Disabled
Display shows "tr n"
Tracking Enabled
Display shows "tr Y"
Click Static (-) to save
selection and advance to
"Factory Default."
Single-pulse the remote line
to save selection and ad-
vance to "Factory Default."
Factory De-
fault Set-
tings
Click Dynamic (+) to tog-
gle between selections.
Double-pulse the remote line
to toggle between selections.
Returns to factory default
factory settings
Factory Default Settings
Not Selected
Display shows "Fd n"
Factory Default Settings
Selected
Display shows "Fd Y"
Click Static (-) to save
selection and advance to
"Display Orientation."
Single-pulse the remote line
to save selection and ad-
vance to "Display Orienta-
tion."
Display Ori-
entation
Click Dynamic (+) to tog-
gle between selections.
Double-pulse the remote line
to toggle between selections.
Inverts display to read
"upside-down"
Normal
For example: 1234
Inverted
For example:
Click Static (-) to return
to RUN mode.
Single-pulse the remote line
to return to RUN mode.
NOTE: Icons do not invert.
D10 Expert™ - Analog and Discrete Outputs
14 www.bannerengineering.com - tel: 763-544-3164 P/N 65448_web
rev. F