350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 16 of 30
Table 7–10: Altimeter output format – Ulvertech Bathymetric system
7.3.3.3 Simrad UK90
The Simrad UK90 transmits data at 4800 baud using 8 data bits, 2 stop bits and no
parity.
Table 7–11: Altimeter output format – Simrad UK90
Notes:
1. The Simrad UK90 altimeter measures altitude at twice the rate that it measures
depth. It therefore includes the altitude field twice in each data packet, separated
by a space character. Both altitude fields will contain similar values because it is
unlikely the altitude will change significantly during the short interval between the
two measurements.
2. The contents of these output data fields are set externally and have no effect on
operation of the 350 System.
7.3.3.4 OSEL Bathymetric System
The OSEL Bathymetric system transmits data at 9600 baud using 8 data bits, 1 stop
bit and no parity.
Commenti su questo manuale