9 – Maintenance
DPN 402197 © TSS (International) Ltd Page 9 of 26
9.2 DISASSEMBLY AND REASSEMBLY
WARNING
ELECTRICAL HAZARD
Mains power supply voltages can cause death or serious injury by electric shock.
Only a competent engineer who has received the relevant training and experience
should perform maintenance work on electrical equipment.
Power-off and isolate the equipment from the electrical supply before you work on any
equipment that uses a mains power supply. Arrange to discharge any power supply
storage capacitors safely.
Observe all relevant local and national safety regulations while you perform any main-
tenance work on electrically powered equipment.
Do not connect the equipment to an electrical supply until you have refitted all safety
covers and ground connections.
9.2.1 Surface Display Computer
CAUTION
Many components within the SDC are susceptible to damage due to electrostatic dis-
charge. You must take precautions against such damage: These precautions include
the use of a grounded conductive mat and wrist-strap. TSS (International) Ltd will not
accept responsibility for any damage caused by failure to take such precautionary
measures.
The following instructions are valid for the SDC Type 9 that the 350 Cable Survey Sys-
tem is shipped with. The 350 System will not work with earlier versions of our SDCs
due to this being the first system to operate under the Windows
TM
environment. Con-
tact TSS (International) Ltd for advice if necessary.
You will NOT need to disassemble the SDC if you must change the communication set-
tings. It is externally configurable using a tristate switch on the Converter Card.
9.2.2 Sub-sea Electronics Pod
CAUTION
Many components within the SEP are susceptible to damage due to electrostatic dis-
charge. You must take precautions against such damage: These precautions include
the use of a grounded conductive mat and wrist-strap. TSS will not accept responsibil-
ity for any damage caused by failure to take such precautionary measures.
To disassemble and reassemble the SEP you will need the following tools and facili-
ties:
A clean anti-static work area
A 3mm hexagonal key