4 – Electrical Installation
DPN 402197 © TSS (International) Ltd Page 9 of 18
Choose one of the two available methods that you may use to connect the altimeter:
1. Direct connection to the SEP. Refer to sub-section 4.1.5.1.
The SEP provides a DC power supply to drive the Datasonics altimeter if you con-
nect it to the ‘Altimeter’ port on the SEP.
2. Connection through the umbilical to the SDC. Refer to sub-section 4.1.5.2.
Available for use with all types of altimeter compatible with the 350 System.
These altimeters use RS232 communications. To send their signals through the
umbilical, you must add them to the ROV multiplex unit and extract them at the
surface. You must also provide a separate power supply for the altimeter.
Generally, these types of altimeter have different data formats. Refer to sub-section
7.3.3 for details of these formats.
4.1.5.1 Direct connection to the SEP
Route the cable from the Datasonics altimeter to the SEP. Secure the cable at regular
intervals along fixed frame members of the ROV. Avoid introducing any sharp bends
or other points of mechanical stress along the cable.
Follow the important advice listed in sub-section 4.1.2 concerning the care of connec-
tors.
Connect the cable to the 6-way ‘Altimeter’ port of the SEP. Tighten the knurled lock-
ing collar by hand only. Do not over tighten this connector.
Use the SDC display software to configure the 350 System for use with the Datason-
ics altimeter connected to the SEP. Refer to Section 6 for appropriate instructions.
4.1.5.2 Connection to the SDC
Make the following provisions if you intend to use one of the compatible alternative
altimeters with the 350 System:
Connect the altimeter to an available SDC serial port. Note that, because the
altimeters use RS232 communications, they cannot transmit their signals farther
than approximately 15 metres. Therefore, you must add the altimeter signals to
the ROV multiplexer and then extract them at the surface. You must then convert
the signals to RS232 for application to the SDC.
Provide a separate power supply to drive the altimeter.
Refer to the manual supplied by the altimeter manufacturer for relevant connection
details.