350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 12 of 26
ADC Board (see Figure 9–4):
IMPORTANT NOTE
The Processor Board holds calibration data for the ADC Board. Therefore, you must
renew the Processor Board and the ADC Board together if you suspect either is faulty.
You will degrade System performance if you do not follow this advice.
1. Unclip and release the 34-way connector PL1. Unclip and release the two 11-way
connectors PL2 and PL3.
2. Use the 3mm hexagonal key to release the four M4 × 12mm screws that secure
the ADC Board to the support block. Remove the ADC Board.
3. Refit the board by reversing the above procedure.
Figure 9–4: ADC Board layout
PL1
PL2
PL3
ADC Board
SD1
SL SV
U1
SD2
PL PV
U20
SD3
PF/A SF/A
U30
18-bit dual channel ADC