4 – Electrical Installation
DPN 402197 © TSS (International) Ltd Page 11 of 18
4.2 SURFACE DISPLAY COMPUTER
Refer to sub-section 2.3 for a description of the SDC and Section 9 for a minimum
specification.
The following sub-sections 4.2.2 to 4.2.4 explain the various connections that you
may make to the SDC.
CAUTION
You must route all cables to the SDC through the rear of the transit case. You must
open and remove the rear panel of the case to allow this.
Figure 4–2: SDC Rear panel with key to ports
4.2.1 Power Connection
Connect AC electrical power to the SDC through the 3-core electrical supply cable
and standard 3-pin IEC electrical inlet.
The SDC has an auto ranging power supply unit that configures itself automatically to
use an electrical supply in its acceptable range 85 to 265V AC (47 to 63Hz).
4.2.2 Communication Link SEP to SDC
Use the SDC port – ‘COMMS FROM POD’
The standard communication link between the SDC and the sub-sea installation of
the 350 System uses RS232. This is a 3-wire link suitable only for communication
over distances up to 15 metres. You may use this method to transmit data to the sur-