
B – Options
DPN 402197 © TSS (International) Ltd Page 7 of 12
B.1.5 Electrical Connection
It is very important that you should interconnect the sub-sea components exactly as
described in Figure B–4 and the instructions below.
IMPORTANT
If the Dualtrack System is an upgrade to an existing 440 System, you must open the
440 SEP and set it to use RS232 communications. Refer to sub-section 4.2.2.1 of the
440 Manual for instructions to change the communication method used by the 440
SEP.
Figure B–4: Electrical interconnection of sub-sea components
CAUTION
To avoid damage to either of the SEPs, make certain that you fit the blanking plugs
supplied by TSS (International) Ltd to any unused ports.
Failure to take this precaution might allow water to penetrate the SEP housings, follow-
ing which total circuit failure will occur.
350 Sub-sea Components
440 Sub-sea Components
Power / Comms
cable
440-to-350 Link Cable
Length 2.5m
TSS P/N 601814
POWER / COMMS
connector
AUX OUTPUT
connector
Sub-sea altimeter
must be connected to the
Altimeter port of the 440 SEP
Commenti su questo manuale