350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 28 of 30
Be aware of a possible degradation in measurement accuracy when operating the
350 System near ferrous rock dumps.
Earth Return Path
If the tone-carrying cable runs parallel with and close to a good conductor, this
arrangement might introduce a shorter earth return path for the tone current. In very
severe cases, the shorter return path might cause errors to appear in measurements
made by the 350 System.
In these conditions, the characteristics of the return path are uncertain, making it
impossible to predict the magnitude of errors.
Summary:
Be aware that errors might exist in data acquired by the 350 System when you oper-
ate it over saturated sand or where a nearby conductive structure, such as a pipeline,
runs alongside the cable.
Curved Target Course
If the target cable has been laid along a course that includes loops or curves as
shown in Figure 7–5, the magnetic fields radiated by the tone will be distorted unpre-
dictably throughout the affected areas.
Under these conditions, the measurement accuracy of the 350 System will degrade
unpredictably.
Figure 7–5: Curved target
Summary:
Be aware that errors might exist in data acquired by the 350 System when you use it
to survey targets that do not follow an approximately straight course.